Asante Gluco View CGM is a continuous glucose monitoring system designed for diabetes management and healthy glucose control. It uses miniature subcutaneous sensing technology to provide painless, round-the-clock glucose monitoring for up to 14 days without finger-prick blood sampling.
Glucose data automatically transfers to the mobile app every 5 minutes. Clinical validation shows a mean absolute relative difference (MARD) of 6.75%. With IP28 water resistance and smart real-time high and low glucose alerts, the system offers a comprehensive, professional and hassle-free glucose tracking experience.
Validated Clinical Performance
Multicentre clinical trials have demonstrated the Asante Gluco View system’s excellent clinical accuracy and safety in both home monitoring and healthcare settings:
- Mean absolute relative difference (MARD): MARD is as low as 6.75% in outpatients and 7.12% in hospitalised patients. A lower MARD indicates closer agreement with laboratory reference plasma glucose measurements and greater accuracy.
- Clarke Error Grid Analysis — Zones A and B: Clinical accuracy reaches 99.8% in outpatients and 100% in hospitalised patients, ensuring medical-grade clinical safety.
- High-glucose alert detection rate: The outpatient high-glucose detection rate reaches 98.6%, providing accurate alerts for key glucose-related risks and around-the-clock health protection.
What Is MARD, and Why Is It So Important?
MARD stands for mean absolute relative difference, commonly translated into Chinese as the “average absolute relative difference”.
In continuous glucose monitoring (CGM), MARD is currently the most fundamental and authoritative internationally recognised measure for assessing the accuracy of a CGM system.
The Mathematical Meaning of MARD and How It Is Calculated
In simple terms, MARD calculates the average percentage difference between CGM readings and laboratory reference glucose measurements, such as plasma glucose testing using a venous blood sample.
Why MARD Matters for CGM
1. Medical Safety and Medication Decisions
People with diabetes, particularly those with type 1 diabetes or those who use insulin, often need to use CGM glucose readings to decide how many units of insulin to administer or how much carbohydrate to consume.
- Insufficient accuracy — a high MARD: If the actual glucose level is 3.5 mmol/L, indicating hypoglycaemia, but the device displays 5.5 mmol/L, indicating a normal level, the user may miss the best opportunity to consume glucose. This could lead to severe hypoglycaemia and coma.
- High accuracy — a MARD below 10%: This ensures reliable glucose trends and alerts and substantially reduces the risk of medication errors caused by misinterpretation.
2. The Key to Finger-Prick-Free, Calibration-Free Use
Traditional glucose monitoring requires frequent finger-prick blood sampling. Current medical regulations and technical standards require CGM systems to achieve extremely high accuracy, typically a MARD below 10%, before regulatory authorities and healthcare institutions permit claims such as “factory-calibrated” and “painless everyday use without finger pricks”.
3. A Common Standard for International Clinical Certification
During medical device registration, such as review by the US Food and Drug Administration (FDA), European Union CE marking, or China’s National Medical Products Administration (NMPA) registration, regulators use MARD data from clinical trials as a key review criterion. In the medical industry and clinical literature, MARD is the most authoritative common measure for comparing performance across brands.
When choosing or evaluating a CGM system, MARD serves as the device’s “accuracy identity card”. A lower MARD percentage indicates more reliable data, offering greater reassurance for everyday glucose management, overnight alert protection, and diet and exercise management.
Reference Guide to MARD Quality Levels
| MARD range | Accuracy level | Clinical significance and applications |
| < 10% | Medical-grade high accuracy | The standard achieved by leading mainstream CGM systems currently on the market, for example 6.75%–8.1%. Can support finger-prick-free use and assist with medication decisions. |
| 10%–15% | Acceptable / national-standard threshold | Meets the minimum requirements for general national certification, for example a national standard of < 15%. Suitable for everyday health tracking; however, finger-prick blood glucose confirmation is still recommended for important decisions. |
| > 15% | Lower accuracy | Larger measurement errors may cause false alerts. Not recommended as the sole basis for medical glucose-management decisions. |
Core Product Highlights
- Painless monitoring without finger pricks: An ultra-thin miniature subcutaneous sensor replaces the discomfort and inconvenience of frequent daily finger-prick blood sampling.
- Automatic updates every 5 minutes and continuous 24-hour tracking: Glucose data automatically synchronises with the mobile phone every 5 minutes, accumulating 288 data points each day so that glucose fluctuations can be monitored around the clock.
- Smart real-time high and low glucose alerts: Customise high and low glucose alert thresholds. When glucose readings fall outside the normal range, the system immediately sends a notification, effectively helping to prevent the risks of unrecognised hypoglycaemia and hyperglycaemia.
- Factory-calibrated and ready after warm-up: The sensor undergoes precise calibration before leaving the factory. After application and a 60-minute warm-up period, users can view real-time glucose readings directly, saving time and effort.
- Advanced IP28 water resistance: Supports everyday showering, bathing and swimming in water up to 1.5 metres deep for a maximum of 2 hours, allowing exercise and leisure activities without restrictions.
- Professional AGP reports: Automatically generates standardised ambulatory glucose profile (AGP) reports and daily glucose curves to help users and healthcare professionals make more precise glucose-management decisions.
Specifications and Technical Performance
| Parameter | Specification |
| Product name | Asante Gluco View Continuous Glucose Monitoring System |
| Glucose measurement range | 2.0–25.0 mmol/L |
| Accuracy — MARD | Outpatients: 6.75%; hospitalised patients: 7.12% |
| Linear deviation | Deviation across the full measurement range: < ±0.83 mmol/L or ±15%, whichever is greater |
| Device dimensions and weight | Ultra-thin, integrated design measuring just 29.8 × 20 × 5.4 mm for discreet, unobtrusive wear. No weight value is provided on the source page. |
| Data storage and transmission | Built-in memory stores 14 days of complete data. Unobstructed Bluetooth transmission range is 6 metres or more. |
| Warm-up time | 60 minutes |
| Water-resistance rating | IP28 |
Dedicated Asante Gluco View Mobile App: Futan
The dedicated Asante Gluco View mobile app is your portable, round-the-clock smart glucose-management assistant. Working with the miniature Asante CGM sensor, the app automatically receives and updates the latest glucose data every 5 minutes, accumulating 288 accurate data points per day and overcoming the time and frequency limitations of traditional finger-prick testing.
- Real-time data synchronisation and trend graphs: A clear, intuitive interface lets you check your current glucose level and changing trends at any time, making it easy to understand the immediate effects of meals, exercise and daily routines on glucose levels.
- Smart real-time high and low glucose alerts: Users can customise high and low glucose alert thresholds. When glucose levels rise abnormally or fall rapidly, the app immediately issues audible alerts and notifications, accurately identifying the risk of unrecognised nocturnal hypoglycaemia and providing greater reassurance for users and their families.
- Automatically generated professional AGP reports: Export internationally standardised ambulatory glucose profile (AGP) reports and time in range (TIR) analyses with a single tap. These reports help users and their healthcare teams assess glucose-management outcomes more accurately and adjust their health plans.
- Ultra-fast, one-second Bluetooth pairing: Supports both iOS and Android. The system is factory-calibrated. Turn on Bluetooth and scan the QR code on the outer packaging to complete pairing quickly and start monitoring.
Whether for everyday health tracking or clinical diabetes management, the Asante CGM app helps turn complex glucose fluctuations into clear, easy-to-understand visual data, making evidence-based glucose management simpler and more efficient.
Who Is Asante CGM Suitable For?
- People with type 1 diabetes or severe diabetes who require insulin injections: Provides continuous 24-hour glucose monitoring to help users track glucose levels at any time and adjust insulin doses accurately, while avoiding the discomfort of frequent daily finger-prick blood sampling.
- People with type 2 diabetes and other people with diabetes: Dynamic glucose trends help users understand how different foods, the order in which they eat, and eating speed affect glucose levels, supporting adjustments to everyday diet and glucose-management strategies.
- People with prediabetes: Helps detect hidden problems early, such as abnormal early-morning glucose rises or reactive hypoglycaemia after meals. Dietary intervention can then help reduce major glucose fluctuations and lower the risk of progressing to diabetes.
- People managing body composition, losing weight or training for sport: Use the app to observe the effects of food on glucose levels in real time, proactively reduce high-glycaemic snacks and refined sugars, and take an evidence-based approach to weight and body-composition management.
- Older adults whose family members need to monitor their glucose remotely: Once the older adult wears the sensor, family members can view real-time glucose data remotely through the mobile app and receive alerts when abnormal high or low glucose levels occur.
Precautions for Use
This product is primarily intended for adults aged 18 and over. It must not be used by children under 2 years of age, patients undergoing haemodialysis, or during magnetic resonance imaging (MRI) scans. If you have a risk of blood-clotting problems or are allergic to medical adhesive tape, consult a doctor for assessment before use.
Frequently Asked Questions
1. What is a CGM continuous glucose monitoring system? How does Asante Gluco View work?
CGM stands for continuous glucose monitoring. Asante Gluco View uses a miniature sensor inserted beneath the skin of the upper arm to measure glucose concentrations in the interstitial fluid. It automatically transmits glucose data to the mobile app every 5 minutes, providing uninterrupted glucose trend tracking 24 hours a day.
2. Does Asante CGM require daily calibration with finger-prick blood glucose readings?
No. Asante Gluco View uses factory-calibrated technology, so it can be used without finger-prick blood sampling. Verification with a conventional finger-prick blood glucose meter is recommended only when your symptoms do not match the system readings or when you have concerns about the data.
3. How accurate is the Asante Gluco View CGM system, and what is its MARD value?
Validated through multicentre clinical trials, Asante Gluco View has a mean absolute relative difference (MARD) as low as 6.75% (7.12% in hospitalised patients). A lower MARD value indicates greater measurement accuracy, and the system has achieved a high level of medical-grade accuracy.
4. Can I shower, soak in hot springs, or swim while wearing Asante CGM? What is its water-resistance rating?
Yes. The Asante Gluco View sensor has an IP28 water-resistance rating, allowing everyday showering, bathing or swimming in water up to 1.5 metres deep for up to 2 hours, without interfering with your normal exercise or social activities.
5. Where should the Asante Gluco View CGM sensor be worn?
The recommended placement is the upper rear area of the upper arm. When applying the sensor, avoid joints, muscles, scars, moles, lumps, and areas where the skin is frequently stretched or exposed to friction to ensure accurate data and secure patch adhesion.
6. How soon after applying Asante CGM can I start reading glucose data?
After applying the sensor and completing pairing by scanning the code in the app, you must wait for a 60-minute warm-up period. Once the warm-up is complete, the app will begin displaying real-time glucose readings and glucose fluctuation graphs.
7. How many days can one Asante CGM sensor be used?
A single sensor can be used continuously for up to 14 days. During this period, the system automatically updates the data every 5 minutes, providing 288 glucose data points per day to support glucose health around the clock.
8. How does Asante CGM help prevent hypoglycaemia? Does it provide real-time alerts?
Yes. Users can customise high and low glucose alert thresholds in the accompanying app. When glucose levels drop rapidly or rise above or fall below the preset range, the phone will issue a real-time alert, helping users promptly identify the risks of unrecognised nocturnal hypoglycaemia and hyperglycaemia.
9. What is an AGP ambulatory glucose profile? How does the Asante app help with glucose management?
An ambulatory glucose profile (AGP) is an internationally standardised glucose monitoring report. The Asante app automatically consolidates 14 days of monitoring data to generate a comprehensive report that includes time in range (TIR), daily glucose curves and glucose variability analysis, making it easier for users and their doctors to adjust their glucose-management plans.
10. Who is Asante Gluco View CGM suitable for? Are there any contraindications?
This product is suitable for adults aged 18 and over who have diabetes or are managing their glucose levels for health purposes and require continuous or periodic glucose monitoring.
The product must not be used by children under 2 years of age, pregnant women, or patients undergoing haemodialysis. It must be removed before a magnetic resonance imaging (MRI) scan. Do not use it in conjunction with an insulin pump or to automatically guide insulin delivery.
繁體中文